HEAT FLUX SENSORS · THERMAL INSTRUMENTATION · SINCE 2015
Heat Flux Sensors for Research, Testing & Thermal Measurement
Measure the heat itself, not just the temperature.
FluxTeq sensors and DAQ systems help researchers and engineers measure heat flux in batteries, buildings, fire testing, materials, aerospace, and thermal management applications.

HTHFS-01 · tested to 1000 °C
Adquisitivo
Three product lines

PHFS-01, PHFS-01e, large-area PHFS-09e and the Ultra-09 plate. The PHFS-01 is 380 microns thin with a built-in Type-T thermocouple. From $110

The threaded HTHF-Probe, with optional water-cooled housing, and the HTHFS-01 for the most extreme surfaces. Engineered to order

COMPAQ DAQ, FluxDAQ and FluxDAQ+. 8 differential inputs, 1–2 µV resolution, real-time plots. From $315
Where it gets used

Cell heat generation, cooling validation, thermal runaway studies.
High-temperature sensors for combustion and spacecraft environments.
Combustion and fire research, protective clothing tests.
In-situ R-value of walls, roofs and windows, non-invasive.
REUNIRSE


NUESTRA HISTORIA.
Fundada en 2015, FluxTeq fue la primera empresa en patentar un proceso de fabricación para la producción en masa de sensores de flujo de calor de película delgada. Siendo la primera de su tipo, FluxTeq es la única empresa que puede desarrollar dichos sensores a granel y venderlos a una fracción del costo de los sensores comparables en el mercado. Desde entonces, FluxTeq ha seguido desarrollando y comercializando nuevos productos de sensores térmicos utilizando la última y más avanzada tecnología.
NUESTRA VISION.
Nuestro objetivo es cambiar la forma en que las personas piensan sobre el calor y la temperatura al ser los primeros en ofrecer sensores de flujo de calor a bajo costo para el uso diario. Si bien conocer la temperatura de algo puede ser útil, conocer el flujo de calor real midiéndolo directamente puede ser mucho más predictivo y útil en cualquier aplicación que implique transferencia de calor.
NUESTRO TEQ.
Nuestro proceso patentado permite la producción en masa de sensores de flujo de calor de montaje superficial delgados y flexibles. Estos sensores de uso general se pueden colocar en cualquier superficie para medir el flujo de calor directamente en unidades de W / m2. Continuamos desarrollando nuevos productos de sensores de primera línea para mediciones de flujo de calor y temperatura.
El sensor de flujo de calor
Ventaja
NUESTROS PRODUCTOS

Small, low-cost, multipurpose

Large and highly sensitive for big surfaces

Ultra-sensitive for building science, soil studies, etc.

Robust, high temp sensors for extreme environments

High-resolution heat flux/ thermocouple loggers
What is a heat flux sensor?
A heat flux sensor (also called a heat flux transducer, heat flux meter or heat flux gauge) measures how much heat is flowing through a surface, in watts per square meter (W/m²). A temperature sensor tells you how hot something is; a heat flux sensor tells you how fast heat is moving into or out of it, and in which direction.
FluxTeq heat flux sensors are thin-film thermopiles. Heat passing through the sensor creates a small temperature difference across it, and the sensor turns that difference into a DC voltage proportional to the heat flux. Every sensor ships with its own calibrated sensitivity value, so the measured voltage converts directly to W/m².
How do I choose a heat flux sensor?
1. How hot does the surface get? FluxTeq PHFS thin-film sensors work from -50 to 120 °C. The HTHFS-01 and HTHF-Probe are built for extreme environments up to 1000 °C.
2. How much heat flux do you expect? Low heat flux, such as a building wall or insulation, needs a large, sensitive sensor (PHFS-09e or Ultra-09). High heat flux, such as a battery cell, electronics or a heated plate, suits a small sensor (PHFS-01, NuFLUX-M).
3. Is the surface flat or curved? The PHFS-01 and NuFLUX-M are thin and flexible and mount on curved surfaces. The copper-clad PHFS-01e is stiffer and more durable.
4. How many do you need? One to a few sensors: PHFS-01 at $110. Many sensors, or a sensor built into a product: PHFS-OEM at $70 each (minimum 4), with volume pricing.
You also need something to read the signal. Heat flux sensors output microvolts, so the reader should resolve about 1 µV. FluxTeq’s COMPAQ DAQ ($315), FluxDAQ ($450) and FluxDAQ+ ($670) are made for this and include Windows software. Small orders of PHFS sensors and DAQ systems typically ship in 1–2 business days.
Solicite un sensor de flujo de calor PHFS y utilícelo con nuestro FluxDAQ sistema de adquisición de datos o FluxDAQ + registrador de datos.
Resolución de medición ultra alta (1-2 microvoltios)
8 entradas diferenciales (flujo de calor / termopares)
V er parcelas en tiempo real
Grabe los datos del sensor a lo largo del tiempo en una tarjeta de memoria SD
Utilice los sensores de flujo de calor de área de superficie grande PHFS-09e o la placa de flujo de calor para el monitoreo del valor R in situ de las paredes de los edificios.