APPLICATION · BUILDING ENVELOPE
Heat Flux Sensors for In-Situ R-Value & U-Value Building Envelope Testing
Measure the heat actually moving through a wall, roof or floor, in place. With indoor and outdoor temperatures, heat flux gives the real R-value and U-value of the assembly as built.

3 studies
below used FluxTeq PHFS-09e sensors, two of them from U.S. national laboratories
~20 sensors
in one Lawrence Berkeley National Laboratory model-validation study
Ultra-09
our most sensitive plate, for highly insulated assemblies
From $420
PHFS-09e large-area sensor
RESEARCH SUMMARIZED BELOW WAS PUBLISHED BY
Pacific Northwest National Laboratory / U.S. Department of Energy · Lawrence Berkeley National Laboratory · Buildings (MDPI)
Why Heat Flux Sensors for In-Situ R-Value Testing?
Temperature alone does not tell you how much heat is moving through a wall, roof, floor or window. Two surfaces can sit at similar temperatures while passing very different amounts of heat, depending on insulation, thermal bridging, solar exposure, air leakage and moisture. A heat flux sensor measures the heat flow directly.
In-situ R-value and U-value
Heat flux with indoor and outdoor temperatures gives the real thermal resistance of an assembly.
Wall retrofit monitoring
Compare retrofit systems by measured heat flow, before and after.
Thermal bridges
Find and quantify bridging at columns, slabs and framing.
Insulation comparison
Compare insulation systems under the same conditions.
Energy model validation
Measured surface heat flow to check EnergyPlus, DOE-2 and other building energy models.
Long-term monitoring
Thermal and hygrothermal monitoring of walls, floors, ceilings and windows.
Recommended products


Ultra-09
Ultra-sensitive heat flux plate for highly insulated assemblies and very low heat flux.
$675 View sensor →

Want a complete kit? The R-Value Measurement System ($1,080) is a ready-to-use system for in-situ R-value testing.
In published research
The studies below were conducted by independent researchers. FluxTeq did not design, perform or validate the experiments. They are shown as examples of how FluxTeq sensors and DAQ systems have been used in building envelope research.
PNNL / U.S. DEPARTMENT OF ENERGY · 2022
NATIONAL LABORATORY REPORT
Wall Upgrades for Energy Retrofits: A Techno-Economic Study
MEASURED WITH
PHFS-09e
The study. Evaluated wall retrofit strategies for older homes on energy savings, moisture performance, constructability and cost. The report notes that nearly 70% of U.S. residential housing stock was built before 1992, much of it with little or no wall insulation. Fourteen retrofit configurations and two baseline walls were tested at the University of Minnesota’s Cloquet Residential Research Facility.
How heat flux was measured. FluxTeq PHFS-09e sensors were installed in the wall assemblies as part of the in-situ data collection, on the interior surface of the drywall, alongside Type-T thermocouples, relative humidity sensors and moisture-content sensors.

LAWRENCE BERKELEY NATIONAL LABORATORY · 2020
NATIONAL LABORATORY REPORT
Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 Using FLEXLAB Measurements
MEASURED WITH
About 20 PHFS-09e sensors
The study. Used measured data from the FLEXLAB test facility to validate heating and cooling load predictions from EnergyPlus, DOE-2.1e and DOE-2.2.
How heat flux was measured. The report’s sensor table lists “Heat flux meter, FluxTeq PHFS-09e” as the majority heat flux meter type, with approximately 20 sensors measuring surface heat flow through walls, floor, ceiling, window glazing, frames and mullions. Data were sampled every second and averaged to one-minute values.
Reported result. The three simulation engines agreed with FLEXLAB measurements to a similar degree, with average range-normalized root mean square errors of about 9–12%.
BUILDINGS (MDPI) · 2022
PEER-REVIEWED JOURNAL
Solutions for Exposed Structural Concrete Bridged Elements for a More Sustainable Concrete Construction in Hot Climates
MEASURED WITH
PHFS-09e with FluxDAQ+
The study. Monitored thermal bridging in three west-facing residential buildings in Riyadh with different wall constructions: uninsulated concrete block, insulated concrete block, and double-layer volcanic block with insulation.
How heat flux was measured. The researchers used FluxTeq PHFS-09e heat flux and surface temperature sensors with a FluxDAQ+ data logger, placed on concrete columns and in-fill wall sections to compare heat flow through bridged concrete and insulated wall areas.
Reported result. Heat loss across uninsulated cast-in-place concrete elements was more than double that across insulated wall portions. Neglecting solar radiation on the west façade could produce errors above 50%, and external insulation could cut the thermal bridging impact by up to 73%.
Common questions
How do you measure R-value in place?
Mount a heat flux sensor on the interior surface and record heat flux with the indoor and outdoor surface temperatures. R-value is the temperature difference divided by the heat flux, averaged over a period long enough to smooth out daily swings.
Which sensor for a highly insulated wall?
The Ultra-09 plate. It is the most sensitive FluxTeq sensor and resolves the very low heat flux of high-R assemblies. The PHFS-09e suits typical walls, floors and windows.
What logs the data?
The FluxDAQ+ logs several heat flux and temperature channels for field studies.
Is there a complete kit?
Yes. The R-Value Measurement System ($1,080) is a ready-to-use system for in-situ R-value testing.