APPLICATION · BATTERY THERMAL
Heat Flux Sensors for Lithium-Ion Battery Thermal Runaway & Thermal Management
See how much heat a lithium-ion cell makes, and where it goes. A thin FluxTeq sensor on the cell surface measures the rate of heat transfer directly, which temperature alone cannot show.

2 studies
below measured cell heat flux with a FluxTeq PHFS-01 and FluxTeq DAQ
380 µm
PHFS-01 thickness: thin and flexible on a cell surface
NIST
traceable calibration, with a sensitivity for each sensor
From $110
per sensor, with volume and OEM pricing
RESEARCH SUMMARIZED BELOW WAS PUBLISHED IN
Batteries (MDPI) · Journal of Energy Storage · Universidad de Chile
What battery researchers measure
Cell temperature shows how hot a surface gets. Heat flux shows how fast heat is generated, absorbed or passed to the next cell, which is what thermal models and cooling designs depend on.
Heat generation
The heat a cell releases during charge, discharge and drive cycles.
Calorimetry and energy balance
Close the energy balance on a cell or module with a direct heat flow measurement.
Model validation
Check CFD, lumped and electrochemical-thermal models against measured heat flux.
Cooling performance
Compare cold plates, air cooling and phase-change materials by the heat they remove.
Thermal runaway studies
Heat transfer to neighboring cells in mitigation and propagation studies.
Propagation barriers
Evaluate insulation and barrier materials between cells.
Recommended sensors

PHFS-01
Flexible, low-profile heat flux and temperature measurements on a cell surface.
$110 View sensor →


HTHFS-01
Abuse testing, fire exposure and thermal shielding studies, to 1000 °C.
Quote View sensor →
Reading the sensor: a PocketDAQ ($189) reads one PHFS sensor wirelessly, and a COMPAQ DAQ ($315) reads up to four. Mapping temperature across a cell face? See thin-film thermocouple arrays.
In published research
The studies below were conducted by independent researchers. FluxTeq did not design, perform or validate the experiments. They are shown as examples of how FluxTeq sensors and DAQ systems have been used in battery thermal research.
BATTERIES (MDPI) · 2020
PEER-REVIEWED JOURNAL
Thermal Modeling Approaches for a LiCoO₂ Lithium-ion Battery: A Comparative Study with Experimental Validation
MEASURED WITH
PHFS-01 with FluxTeq DAQ
The study. Compared three thermal models of a LiCoO₂ 26650 cell: a lumped model, a 3D-CFD model and an electrochemical NTGK model. Simulations were validated against cell-surface measurements under constant-current discharge and a highway driving cycle.
How heat flux was measured. The paper states that heat flux from the cell was measured with a FluxTeq PHFS-01 connected to a FluxTeq DAQ, and plots the measured heat flux at different discharge rates.
Reported result. At 1.5C the maximum temperature rise was 18.1 °C, and the electrochemical model was within 1.3 °C of the measurement.




UNIVERSIDAD DE CHILE · 2022
DOCTORAL THESIS
Thermal Behavior and Stability Study of a Lithium-Ion Battery Pack With Air Cooling
MEASURED WITH
PHFS-01 with FluxTeq DAQ
The study. Thermal behavior of an air-cooled module of cylindrical LiCoO₂ 26650 cells: single-cell thermal modeling, module temperature testing, forced-air cooling, particle-filter temperature estimation and a thermal abuse model for thermal runaway stability.
How heat flux was measured. The thesis states that heat flux from the cell was measured with a FluxTeq PHFS-01 connected to a FluxTeq DAQ, plotted at different discharge rates.
Reported result. For the modeled cell under free convection, thermal runaway was triggered above 145 °C.
JOURNAL OF ENERGY STORAGE · 2026
PEER-REVIEWED JOURNAL · RELATED METHOD
Innovative 3D-Printed Hybrid Cooling Systems for Thermal Management of Lithium-Ion Pouch Cells
RELEVANT SENSOR TYPE
Thin surface heat flux sensors (PHFS-style)
The study. A 3D-printed hybrid thermal management system for pouch cells that combines liquid cooling with a composite phase-change material in a lightweight hexagonal structure.
Reported result. The authors report peak battery temperatures up to 35 °C lower than with standalone cooling approaches, and describe the system as a way to reduce thermal runaway risk.
Why it is here. It is an example of the cooling-performance work where a thin surface heat flux sensor shows how much heat a cooling design removes.
Common questions
Which sensor fits a cylindrical or pouch cell?
The PHFS-01 is 380 microns thick and flexible, with a 1 in × 1 in sensing area. The published studies above used it on 26650 cylindrical cells.
What temperature range does it cover?
The PHFS-01 is rated from −50 to +120 °C. For abuse and thermal runaway testing above that, use the HTHFS-01, rated to 1000 °C.
Do I need a special DAQ?
The sensor outputs a small voltage, so resolution matters. FluxTeq DAQs read at 1–2 µV resolution and read the sensor’s built-in thermocouple as well.
Can FluxTeq supply sensors in volume for a battery product or test program?
Yes. The PHFS-OEM is $70 per sensor with a minimum order of four and lower pricing at volume, and custom sensor sizes are available.